A-A-52460
TABLE I. Filtering efficiency.
Test duration (hours) |
Flow rate (gph) |
Maximum contaminant add rate-grams/hour |
Minimum filtering efficiency percent (%) at 0.1 hour |
Minimum filtering efficiency (%) at 1.0 hour |
Minimum filtering efficiency (%) at end of test |
3 |
21 |
0.6 |
65 |
85 |
95 |
TABLE II. Contaminant size.
Coarse contaminant |
|
Particle size in micrometer |
Percent by weight |
0-5 |
12 ± 2 |
5-10 |
12 ± 3 |
10-20 |
14 ± 3 |
20-40 |
23 ± 3 |
40-80 |
30 ± 3 |
80-200 |
9 ± 3 |
QUALITY ASSURANCE PROVISION
a. Responsibility for inspection. The contractor is responsible for the performance of all inspections (examinations and tests).
b. Contractor certification. The contractor shall certify and maintain substantiating evidence that the product offered meets the salient characteristics of this commercial item description and that the product conforms to the producer’s own drawings, specifications, workmanship standards, and quality assurance practices. Items with known defects shall not be submitted for Government acceptance. The Government reserves the right to require proof of such conformance prior to the first delivery and thereafter as may be otherwise provided for under the provisions of the contract.
PRESERVATION, PACKAGING, PACKING, LABELING, AND MARKING
Preservation, packaging, packing, labeling, and marking for the desired level shall be as specified in the contract (see note b).
NOTES
(This section contains information of a general or explanatory nature that may be helpful, but is not mandatory.)
a. Addresses for obtaining copies of referenced documents.
1. Government specifications and standards. Copies of A-A-52468 “Gasket: Filter, Fluid, Pressure, Automotive Fuel" are available from the Navy Publications and Printing Service Office, Standardization Documents Bldg. 4D, 700 Robbins Avenue, Philadelphia, PA 19111-5094.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business