MIL-DTL-52649C
1.2.1 Classification. The primer equipment will be classified as one of the following types and sizes:
Description
Size designator
2
2.5 cubic centimeters (cc) discharge, see 3.5.1.
4
4 cc discharge, see 3.5.2.
5
5 cc discharge, see 3.5.3.
6
6 cc discharge, see 3.5.4.
12
12 cc discharge, see 3.5.5.
Description
Type designator
Gas propellant primer equipment system, 18 ounce (oz) cylinder. Use
III
with capacity designator A only, see 1.2.2 and 3.5.6.
Gas propellant fully automatic primer equipment system, 18 oz or 21 oz
V
cylinder. Use with capacity designator A or B, see 1.2.2 and 3.5.7.
1.2.2 Capacity designator. The capacity designator is a letter code used to designate the required
cylinder capacity as follows:
Cylinder capacity
Capacity designator
A
18 oz
B
21 oz
2. APPLICABLE DOCUMENTS
2.1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this
specification. This section does not include documents cited in other sections of this specification or
recommended for additional information or as examples. While every effort had been made to ensure the
completeness of the list, document users are cautioned that they must meet all specified requirements
documents cited in sections 3, 4, or 5 of this specification, whether or not the are listed.
2.2 Government documents.
2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and
handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the
issues of these documents are those cited in the solicitation or contract.
FEDERAL SPECIFICATION
O-F-1044
-
Fuel, Engine Primer: Cold Starting, in
Pressurized and Non-pressurized Containers.
FEDERAL STANDARD
FED-STD-H28
-
Screw-Thread Standards for Federal Services
2