MIL-PRF-62439B(AT)
4.5.3 Performance tests.
4.5.3.1 Minimum fuel flow. To determine conformance to 3.4.1, the fuel control
assembly shall be tested using test equipment specified in 4.2.1 and military aircraft type II
calibrating fluid (see 6.3) or commercial equivalent.
4.5.3.2 Backup valve operation. To determine conformance to 3.4.2, electrical power to
the assembly shall be off and the backup fuel flow shall be measured using the test equipment
specified in 4.2.1 and military aircraft type II calibrating fluid (see 6.3) or commercial
equivalent.
4.5.3.3 Maximum fuel flow. To determine conformance to 3.4.3, the fuel flow shall be
measured using test equipment specified in 4.2.1 and military aircraft type II calibrating fluid
(see 6.3) or commercial equivalent.
4.5.3.4 High pressure relief valve. To determine conformance to 3.4.4, the assembly
shall be visually examined to verify the provision of a relief valve. The assembly shall be tested
using equipment specified in 4.2.1 and military aircraft type II calibrating fluid (see 6.3) or
commercial equivalent to measure pressure at the control discharge port.
4.5.3.5 Fuel flow schedule. To determine conformance to 3.4.5, the assembly scheduled
fuel flow shall be measured using test equipment specified in 4.2.1 and military aircraft type II
calibrating fluid (see 6.3) or commercial equivalent.
4.5.3.6 Cutoff valve and check valve operation. To determine conformance to 3.4.6, the
assembly shall be examined to verify the provision of a combination cutoff and fuel flow check
valve. The assembly shall be tested for opening, closing and leakage with equipment specified
in 4.2.1 and type II calibrating fluid (see 6.3) or commercial equivalent.
4.5.3.7 PTS feedback voltage output. To determine conformance to 3.4.7, the position,
specified dimension and voltage shall be measured using test equipment specified in 4.2.1 and
military aircraft type II calibrating fluid (see 6.3) or commercial equivalent.
4.5.3.8 IGV feedback voltage output. To determine conformance to 3.4.8, the position,
specified dimension and voltage shall be measured using test equipment specified in 4.2.1 and
military aircraft type II calibrating fluid (see 6.3) or commercial equivalent.
4.5.3.9 PTS actuator flow. To determine conformance to 3.4.9, the relationship of the
electrical current to the flow shall be measured using test equipment specified in 4.2.1 and
military aircraft type II calibrating fluid (see 6.3) or commercial equivalent.
4.5.3.10 IGV actuator flow. To determine conformance to 3.4.10, the relationship of the
electrical current to the flow shall be measured using test equipment specified in 4.2.1 and
military aircraft type II calibrating fluid (see 6.3) or commercial equivalent
11