MIL-DTL-62011E
4.6.24 Humidity (see 3.6.10). The pump shall be tested in accordance with method 507 of
MIL-STD-810 and meet the requirements of 3.6.10. Following completion of the humidity test, the pump
shall be pressure and flow tested (see 4.6.3).
5. PACKAGING
5.1 Packaging. For acquisition purposes, the packaging requirements shall be as specified in the
contract or order see (6.2). When packaging of material is to be performed by DoD or in-house
contractor personnel, these personnel need to contact the responsible packaging activity to ascertain
packaging requirements. Packaging requirements are maintained by the Inventory Control Point's
packaging activity within the Military Service or Defense Agency, or within the Military Service's System
Commands. Packaging data retrieval is available from the managing Military Department's or Defense
Agency's automated packaging files, CD-ROM products, or by contacting the responsible packaging
activity.
6. NOTES
(This section contains information of a general or explanatory nature that may be helpful, but is not
mandatory.)
6.1 Intended use. Fuel pumps described in this specification are intended for use in military vehicles.
This fuel pump is military unique because it must be able to operate in an environment from -65 to 130 °F
(-54°C to 54°C), with 25g of shock.
6.2 Acquisition requirements. Acquisition documents should specify the following:
a. Title, number, and date of this specification.
b. Title, number, and date of the applicable specification sheet and the complete PIN.
e. If flexible shielded cable is required and its length (see applicable specification sheet)
f. Packaging (see 5.1).
6.3 Contaminated solid. The test dust described in ISO 12103-1, Road vehicles -- Test dust for filter
evaluation -- Part 1; Arizona test dust, may be used for fuel pump testing (see table VI).
6.4 Subject term (key word) listing.
Gallons per hour
Pressure
Gasoline
Diesel
Motor
Flow
6.5 Changes from previous issue. Marginal notations are not used in this revision to identify
changes with respect to the previous issue, due to the extent of the changes.