METRIC
MIL-PRF-62678B
19 January 2010
SUPERSEDING
MIL-PRF-62678A
22 November 1995
PERFORMANCE SPECIFICATION
PUMP, FUEL, ELECTRICAL: 12 AND 24 VOLT DIRECT CURRENT (METRIC)
This specification is approved for use by all Departments and
Agencies of the Department of Defense.
1. SCOPE
1.1 Scope. This specification covers two types of electrically operated, in-line fuel
pumps for use with 12 and 24 volt direct current (Vdc) automotive electrical systems (see 6.1).
1.2 Classification. Pumps are classified according to type, voltage, polarity, and metric
thread designation, as specified (see 6.2 and 6.3).
Type I
-
Standard duty (630 hours)
Type II
-
Long life (5040 hours)
Grade:
1
-
12 Vdc nominal
2
-
24 Vdc nominal
Class:
1
-
Negative ground
2
-
Positive ground
Thread designation:
1
-
1/8-27 NPTF Female
2
-
1/4-18 NPTF Male
3
-
1/4-18 NPTF Male
Comments, suggestions, or questions on this document should be addressed to
U.S. Army RDECOM, Tank Automotive Research, Development and Engineering Center,
ATTN: RDTA-EN/STND/TRANS MS #268, 6501 E. 11 Mile Road, Warren, MI 48397-5000
or emailed to DAMI_STANDARDIZATION@conus.army.mil. Since contact information can
change, you may want to verify the currency of this address information using the ASSIST
Online database at https://assist.daps.dla.mil.
AMSC N/A
FSC 2910
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.