MIL-PRF-62678B
f.
Federal stock number
Manufacturer s part number
g.
h.
Date of manufacture
i.
U.S.
Inlet shall be marked "IN" and outlet shall be marked "OUT."
j.
3.6 Workmanship. Workmanship shall be such as to assure a product free of chips,
burrs, sharp edges, rust, loose or defective connectors, or faulty soldering and shall not
compromise, limit or reduce the capability of the pump in the performance of its intended use
(see 4.6.2).
4. VERIFICATION
4.1 Classification of inspections. The inspection requirements specified herein are
classified as follows:
a. First article inspection (see 4.3).
b. Conformance inspection (see 4.4).
c. Control tests (see 4.5).
4.2 Inspection conditions. Unless otherwise specified (see 6.2), all inspections shall be
conducted under the following conditions:
a. Air temperature: 24 ± 10C (75 ± 50F)
b. Barometric pressures: 96 (+7, -10) kilopascals (kPa) (13.9 (+1.04, -1.4) pounds
per square inch (psi))
c. Relative humidity: 50 ± 30%
4.3 First article inspection. First article inspection shall be performed on seven samples
of each type, grade, and class when a first article sample is required (see 3.1 and 6.2). This
inspection shall include the examinations of table V and the tests of table II.
6
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business